hayward blue essence troubleshooting

could be the motor, if the shaft has worn unevenly, or if there are grooves or rust on the shaft. Which explains the clicking of the pump. Replacing it involves separating the wet end from the motor end, then holding the shaft so you can unthread the impeller, removing the two old seal halves, and replacing in the same direction or orientation to each other, rethreading on the impeller and reconnecting the seal plate to the pump housing. Does it really need to be replaced? The arrow should point in the same direction as the water flow. Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. IF the shaft spins freely, and your motor hums and trips the breaker, first check the wiring connections on the incoming wires, nice and tight, and no bare wire touching anything except the terminal connector. Is this the proper way to wire this salt water panel or does it also have to have a cable going into N0-2? I bought a new pump thinking was something wrong with pump on off switch. Everything coming in appears to be tight. It worked fine just prior to a filter cleaning. If you pipes are underground, it could also be happening, if flex pipe was used and you have been using chlorine tablets in the skimmer. Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. switch and to the capacitor, to be sure nothing is loose or no crimped wires. WTF! Breville Tamper Coffee Kit 54mm, It DOES turn on. Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. Let everything dry and put the pump on again and it just hums. Hi Carlos, Im not familiar with working on those timers, a built-in to the back cover for Power-Flo pumps. There should be at least 12 of straight pipe before the switch. Hi Don, you have good troubleshooting skills, when flow is poor, it can either be a dirty filter or some obstruction after the pump which raises the filter tank pressure. Great site. Sparking can also come directly from a short in the windings of the motor. HI David, did anyone empty the pump basket recently? Hayward pro lx 1.5hp pump turns on for 5 seconds, shuts off, then light to moderate, white electrical smoke from pump. Shouldnt be having a problem so soon, no but it can happen, but more likely to not be the shaft seal, but the exit pipe, or a leak around the impeller housing, check the bolts around the pump, to be sure they are tight. If so pack a bead of Pool Putty around the fitting, or better yet, cut it out and replace it, using lots of Teflon tape or other thread sealant. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. The control is set for the wrong turbo cell type. A bad shaft seal or loose pipe is likely the cause of your leaky pump. Thanks again! Check the wiring. Just wired and installed a brand new Century 1 hp pump motor on a Hayward Super pump filter, getting power to the terminals of the motor but motor does not start, shaft spins freely. It could also be a loose switch in the back of the motor. I replaced the pump thinking it was bad. You must log in or register to reply here. Good day everyone. This worked well until about 4 years ago, when I replaced it with a similar pump, a Hayward sp2607x10. "width": "611",
men's rhinestone dress shoes. Thanks! Breaker for the pump is not tripped. When the pool guy switched it, it worked very well for about a month with no issues at all. The low speed works fine. Hello, Just bought a house with a pool in January. I also see that some people with the same problem have had a power surge, or incorrect incoming voltage that has caused this error. This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. Im losing my mind. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. When it gets up to speed, the switch is supposed to release the capacitor. Got a new motor, it made humming noise since day on,if i help it spin it works so I changed the capacitor and still the same, humming and if I help it to spin it goes fine, any suggestions? Secondly, check that there are no air leaks in FRONT of the pump, typically around the pump lid, or on the pipe coming into the pump. 1. Im being advised by an electrician that my Hayward pump has a dead short in it. You dont need a seal plate kit you can just use the shaft seal SPX1600Z2. Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). It likely also got hot and the threads shrunk, now drawing in too much air for the pump to catch prime. larger hp motors, are not reversible. It could also be a clogged impeller or clogged filter, or clogged skimmer line. They have never had this issue in the pass, a salt water chlorinator was added to the system last year with no problems. We knows its not electrical. hi I followed the set up directions on my new sp1580lx pump and it keeps tripping the breaker. We purchased a Hayward D.E Filter last summer. La mayora de las veces la vlvula de gas est cerrada, el tanque de propano est bajo, el encendedor est roto o el sensor de fuego no est colocado correctamente. From the EcoStar technical guide: Check impeller and motor shaft for freedom of movement. My issue is that the normal operating pressure is around 13-15 psi. Any ideas on what may be going on? Today it completely shutdown at some point and tripped the breaker in the house. the pop may have been the capacitor blowing, its a black cylinder located at 9 oclock in the rear of the motor. "@type": "ImageObject",
I added new wire and plug end but when I plug it in it trips the breaker. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. It makes humming sound 1-2 times before starting. They just reopened my pool. My Hayward xstream filter pump is not turning on at all. Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. "width": "611",
Also inspect other wires in the back, look for any pinched wires, or wires touching each other. Hi Rick, if thats a new thing, there is probably something loose and leaking (air) when the pump shuts off. UNK the , . Go to the grocery store and come back and its dead. The volute screws (around the impeller housing) do not need to be removed. Last year it worked great. You can remove the pump basket and reach back with your fingers to see if any debris can be felt in the eye of the impeller (pump Off, of course, lol). Fault with the pump wiring. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. If the capacitor doesnt fix it, you may need a new motor, or pump, barring other issues that can be seen readily. I have a hayward superpump and upon starting the pump, it sucks the water into the pump basket but when it is filled with water the pump will start revving up and down. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. Terrible storms 2 nights ago. Or do I have a friction issue in the impeller? The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. "logo": {
That is the black cylinder located in the rear of the motor, at 9 oclock. Can you manually get it to rev-up on a higher speed? It has now been two days since the technician was here and the pump is still pushing de into the pool at lower RPM speed. The instant salinity in both polarities should be about the same (+/- about 200 ppm). Every time I vacuum my pool and then back wash and rinse. Thank you. I immediately unplugged it and the plug was black and the extension Outlet was melted. Flex pipe used on skimmers can eventually narrow and crimp, leaving a small opening that clogs easily. Please help! just replaced t15 on a rev 1.45 aqua rite and the default salt reading now is 4. First time pool owner (obviously dont know what we are doing). Turn it off fully, then back on again. but the digital display panel wont light up, does the propane need to be connected and turned on to make the display panel work?? could be cord problem, too. I am a new pool owner and first Hayward pump. the motor makes humming sound but nothing happened, then the motor became burning hot. Flip circuit breaker all the way Off, then back on again. Armstrong Human Resource Management 13th Edition Pdf, Hi Tony, yes if the impeller spins freely then the shaft does too (unless you are unthreading the impeller from a stationary shaft) normally. I just have a problem with the motor pump, I turn ON Saturday morning and left all day working, On Sunday morning I try to turn on the pump but it only make a noise but water dont flow then it stop working, then on Monday do the same thing it only make noise for 3 minutes then it stop working. well, possibly it just needs to dry out. Question, if I can determine which return pipe is broke could I just block off that return and bypass it. It hums. Third time turned off pump same thing happened with humming and eventually kicking in. The original pump (assy A) smells burnt. Open faced impellers need very large pliers, or a strap wrench, some have special tools to remove open brass impellers. Search our blog for shaft seal replacement, if so. HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 This is wholesale site for our registered customers. If the wiring is Ok and the error persists, replace the sensor. I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. We are a registered 501(c)3 non-profit that is funded by user donations. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-heater-troubleshooting/",
Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. If theres no power at the switch/timer, go back further to the breaker. Hi, We had a pool installed last fall and we are still figuring things out. But, you probably just need a $15 shaft seal, which is not overly difficult to replace. So my Hayward melted the whole left sided plastic shrouds. Hi Jeff, probably that sound is worn bearings (pumps dont have brushes). Tried to vacuum. Once I get it going, it works fine for as long as I leave it on. Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. Hi Theresa, if the pump is overheating, and shutting off for 20 minutes to cool down and then starting again, thats not usually a good sign, altho could be incorrect voltage or loose connections. Second most common air leak on a Super Pump would be the incoming pipe fitting. The correct lateral assy for the S210 filter would be the SX210DA if you used a smaller assy, the pipe wont reach all the way into (inside of) the multiport valve base, and allow sand to enter the pipe but just a theory, you likely used the correct and full height SX210DA? Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. During that time, the pump got really hot and melted the fitting on the top. If dead, you can replace just the motor and shaft seal, re-using the pump and impeller. Inspect the pipe/union connections on the suction side for loose connections or damaged pipes. Filter or pump baskets are dirty. Hi John, the cap for that motor is START CAPACITOR, 161-193 MFD (BC-161) we dont carry it, but easily found online. The air may be there on high speed too, its just not noticeable. If you have an electric shop nearby, they could test it, but if its around 10 yrs old, you may assume its dead. This is a salt pool not sure if that matters in the question. If the flow is normal however, it could be a bad flow switch or pressure switch. Usually however, a howling or moaning sound from the pool heater, is low water flow. Inside there is an o-ring that may be out of position, or need lubricant. Troubleshooting a Salt Chlorinator First, check power. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. I have a Hayward super flo matrix pump. It should be the receiving 115V or 230V, depending on how it is wired, plus/minus 10%. Hi Davy, Pump is 29 years old so wouldnt surprise me if impeller is failing. Find these plugs and remove them by loosening the wingnut and wiggling it out. Hello Davy, you just saved me a few hundred bucks. After cleaning the pool the pool pump would just hum and not start. ), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. Call Hayward and speak to their tech support people, for more precise advice. I just replaced the flow switch and that solved one problem, but now Im only able to produce chlorine when the system is on Super Chlorinate. Check the wiring of the pump cord, comparing to the wiring diagram printed on the motor, to be sure that they are connected properly, should be wired for 115V (not 230V). I completely back washed and clean the system two times making sure the filter was put together properly and there were no holes in either the manifold or the filter grids. Try adding another inch of water. On initial trial for ignition. If you attached the cord, make sure that the wires are correctly attached to the terminal board, and the ground wire secure. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. The most common cause for this is turning the valve with the pump on, or not pushing the valve handle down fully as the valve is re-positioned. $579 + Free Shipping in USA. 3 No air bubbles on my returns when not vacuuming Sir, I have a Hayward Ecostar 3400 variable speed pump and will not run anymore. If yes, the motor bearings are the problem. I have perhaps a really basic question I just cannot get one side of my salt cell to seal with the union. Turned on the motor and smoke and a oil type substance came out of the capacitor. Hi. Is there something special I need to do when first installing the motor? So I need any kind of advice or help you can give me, before I have to call someone out. 1. Inspect wiring for any loose or corroded connections. BUT THE BEARINGS. It would run fine. Can you help me with this problem Robert, Hi Robert, I dont see an error code 11 in the owners manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true start by making sure that the filter is clean, the valves are open, and the pump lid is on tight. We have a few of them, but maybe not the correct one for your motor, replace with the exact same MFD number, printed on the cap. . I dont want to pay someone to come out & charge me more for not knowing what Im doing. Silicone lube can also be used, but dont use petroleum based lubes that can eat the rubber. In most cases, it means that your motor is on the way out. Fix this problem simply by tightening or adjusting the wires and connections in the motor. you can keep running it, while you get parts sure. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. If it still wont catch full prime, open up the pump so you can ream out the impeller vanes with wire or a skinny screwdriver. Does a Hayward super pump wired on 230v have to have a controller?.. Incorrect sizing can cause multiple problems, including low water flow. I even plugged in the old pump and that too did not run? I checked the fuse and its good. I took apart the impeller and didnt see anything that could cause a problem. How do I seal it? My salt was tested today at 3000 and everything else was perfect. Davy, Hmmm, now if the breaker were stopping the power from flowing to the switch, the timeclock would lose time, and would not turn itself on. Hi Donna, the screws that are removed to rotate are the long thru-bolts that run thru the motor, and are turned at the rear of the motor (spray with WD-40 first). If you wire 110V to a 220V motor, it will not usually run, or will only slowly turn. Check the impeller and seal alignment. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. Sandy, some hoses are clamped onto hose adapters, using a worm clamp or radiator clamp that tightens the hose to the hose adapter. Hi Steve, this can be from reduced flow, like a VS pump running on low speed, and some water vaporizing into steam. It leaks from the impeler case and is noisey, so assy B is no replacement. Then, I tried plugged the pump into another power outlet and it still does not work. I have a pump that wants to stop pumping water after a few minutes the flow gets very low. There should be no elbow after the flow switch. Flip the switch opposite, and you should be all set. You can consult the flow charts for each model, to compare flow rates among two pumps, with a given (or assumed) level of resistance (feet of head). We have parts for the Super pump. Excessive voltage or amps can cause the problem. Hi Stephen, your spa waterfall, is that a spillover or an actual waterfall feature? Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. Hi Mark, should it be 115V? BTW, this can be caused from a water hammer effect, running the pump and then shutting off flow suddenly, or the fitting could have been overtightened to begin with, 7 years ago, and age caused it to give way. Missing air bleeder sock or strainer cap Also you can test the outlet with another small plugin item, like a hair dryer or lamp. Recently replaced mortor and pump. Yes, that sounds like a filter problem, clogged up with algae or oily substance. If not, the parts internally, some parts, need replacement. If none of those things, perhaps the filter grid needs to be soaked in a Filter Cleaner, to remove oils or minerals that have clogged the pores of the fabric. "url": "https://intheswim.com/",
Hi, it could be just that, a vibration. You can assist by removing the back cover and placing a fan behind the motor and try again after a day. "@type": "Person",
They do not seem to have enough stooch even though they are rated at 1HP like my original motor. Davy, Your options are to 1). {Thinking it could be the timer motor) Problem still the same. Look on the cap for the MFD number and replace with exact duplicate. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. But dont bypass GFCI protection, thats just to determine if its a motor problem or outlet problem. Loose wire connections or touching terminal connections cause sparking. Also be sure the vent holes for the motor are not blocked. When he went to turn the pool back on it made a slight humming noise like it was trying to come back on but it wouldnt turn on. Is there a trick to moving it to 115? Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. Pressing on/off buttom followed only by click sound of switch. Could it have shut it self off from overheating? Please consider. Hello, I have a H200 natural gas heater . If the control exceeds the maximum number of ignition retries or recycles the heater will shut down and go into lockout. Hi Mary, flocculents usually produce a fluffy precipitate that is vacuumed to waste, because it clogs ups the filter. However, I havent tried to spin the shaft. Do you have any suggestions? Ive checked the voltage coming in before the breaker and after the breaker, (at the motherboard location), replaced the breaker just to be safe, but still, overheats. We are snow birds in AZ and want to drain the system for the summer. Did not raise red flags, amature lol. If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. I have chalked all the connections and lubricated the basket seal. There was alot of debris once I removed the assemblies and some water below wiring. I have replaced my existing super pump with new one. Is the motor set to accept 220V, and matching what you measure at the motor terminals? Hi Heidi, it sounds like maybe the plumbing could be reversed? Usually its 4 bolts or its a clamp band that connects the seal plate to the volute or strainer housing. However, when the filter is running for about 2-3 hours, the pressure increases to 20 psi, and the output water flow is minimal at best (extremely slow). Make sure that there are no blockages in the impeller because the motor will not turn if the impeller cannot rotate. 9-17-2020 how to watch past broadcasts on twitch. No noise, nothing. We used flocculant and vacuumed through the pump instead of to waste. I only rotated the one piece how can the screws not go right back in? After I installed the ne motor, I pugged it in, started the pump and the breaker tripped. Replace cell or entire system Aquatrol RJ with GLX tcell 5, Cheap option for linking a second salt cell, Brand new AquaRite 900 Check Salt and Inspect Cell light, Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Reset the average salt level on startup and whenever you replace your cell. The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Hi Jeff, cant be sure but it sounds like a relay issue, a relay on the controller. Motor wiring is pretty simple, green to ground and the other two wires, doesnt matter which one, go to terminals L1 and L2. If you have other questions, you can email me Davy, at swimmers@intheswim.com. If it continues, a new o-ring might be the ticket, yes. Motor will hum for a few seconds and eventually trip the breaker. If still stumped, use a power meter to find the problem lies where the power dies, and trace power from the breaker to the timer or outlet, to the motor. If it slowly rises your capacitor is capable of holding a charge. When running through all these checks and balances if it is noticed that there is not bond wire or that the tightening screws are not all secure, correct the issue. the tubes are sealed at the end by the two seal plates. There is water, not a lot, but water at the base of the pump. Could be too big for the pipe size, although normally I would think that a 1hp should be fine, but do a wheel RPM test on the cleaner (28-32 RPM of the wheel is ideal), and bleed off excess water pressure at the wall fitting. Hi Jim, check the wire connections, and the voltage coming into the motor. In most cases, if there is a blockage, your pumps pressure increases. Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. i just installed a vspnp hayward pump and when i flip the breaker on it only makes a clicking noise. heres the motor: https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft and the seal: https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2. "@type": "ImageObject",
What should I do? Thank you so much for taking time to answer all our concerns. Or it could be a bad breaker, but usually not. Then sometimes with no rhyme or reason the pump shuts down and will not come back on until after I turn off and on all breakers. When in front of the pump, problems like a clogged impeller, air leak into the pump, or clogged skimmer line, or low water these will produce filter pressure lower than normal (on the filter pressure gauge). Grab it and see if it looks/feels loose. Hi Davy, Could the water have damaged the motor ? If that does not fix the issue, the problem goes deeper, and it may be a fatal error in the motor. Salt cells create cloudy bubbles, Ozonators too. Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. It can continue to run at that point but its almost like its running at 25% power or even less so we just turned it off. Right now I can hear the pump running hard when it is turned on, but pressure gauge shows 0. Then I saw a HS code. What am I not doing? Now when it is turned on it works for a few seconds then stops pumping and makes a humming sound. The price seems steep ($500+ for the pump) and it seems only Leslies carries them. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the ' '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Known for being reliable & durable, Hayward pool pumps have always been our leading line of pumps. Pumps normal pressure and pulls enough volume to keep bakery full. What should I check? So we cannot manually rotate the shaft a full revolution. When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. Or you can buy the bearings and seal, and with a set of bearing pullers you can replace your own. Diffuser broke. Now there is no water running from the pool to the motor basket. But, that may not be it, if you say the shaft is getting stuck each time? I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. I have a Hayward power-flow matrix pump with hayward preflex extended cycle D.E. Hi Davy, "@type": "ImageObject",
Cheers! Hi i have a Hayward super pump when I turn it on it doesnt suck any water from the pool the filter pressure gauge is at 0 when I turn it off it makes a spinning noice. It is being practiced by thousands of pool owners just like you. Do I need to do something else to get it to prime faster? Hmmm, not too sure about this question Jay, there must be some explanation. },
Hi Clara click doesnt sound like a motor runnning, perhaps you are hearing a relay click, but if the motor itself is not turning over there could be a multitude of reasons why, but in most of these cases, the problem lies where the power dies. Or very high mineral content (very hard water), or oily substances. When I went out to drain water from the pool it wouldnt turn on. When I take the lid off the pump hopper I can hear the air releasing, and there cant be any air leaks anywhere as its a new line right from the pump directly into the pool. Automatic restart is 2 minutes after the error is corrected. Hi Bryan, not normal but not uncommon. Bearings produce a loud squealy sound. Checked breakers etc tried again and it came onbut very loud. Guess it is time for a new drive.